新疆石油天然气 ›› 2023, Vol. 19 ›› Issue (3): 72-79.DOI: 10.12388/j.issn.1673-2677.2023.03.011

• 油气开发 • 上一篇    下一篇

酸性气井油管内壁水基缓蚀剂预膜仿真模拟

  

  1. 西南石油大学油气藏地质及开发工程国家重点实验室,四川成都  615000

  • 出版日期:2023-09-10 发布日期:2023-09-10
  • 作者简介:余成秀(1998-),西南石油大学石油与天然气工程专业在读硕士研究生,目前从事油气井工程力学及仿真研究。(Tel)18382074816(E-mail)515828269@qq.com
  • 基金资助:

    国家自然科学基金面上项目“深层页岩多级分段压裂套管变形容忍限研究”(52274042);过程装备与控制工程四川省高校重点实验室项目“高温高压高产气井管柱特殊螺纹设计”(GK202108)

Simulation of Prefilm of Water-Based Corrosion Inhibitors on the Inner Wall of Production Tubing in Sour Gas Wells

  1. State Key Laboratory of Oil & Gas Reservoir Geology and Exploitation,Southwest Petroleum University,Chengdu 610500,Sichuan,China

  • Online:2023-09-10 Published:2023-09-10

摘要:

酸性气井常常伴有CO2、H2S对金属材料的腐蚀,井下喷注水基缓蚀剂预膜防腐技术是一种比较先进且成本较低的方法。但针对缓蚀剂预膜时间、液膜厚度、液膜分布及喷注缓蚀剂周期等参数目前尚未开展系统研究。基于RNG k-ε 模型(Re- normalization group k-ε 模型),结合多相流理论,利用欧拉壁膜模型(EWF模型)耦合模拟水基缓蚀剂液膜的形成和流动,分析缓蚀剂停注后在气流冲刷作用下的流动规律。研究结果表明,在生产工况下酸性气井中的气流能够携带水基缓蚀剂并在管柱壁面上形成厚度约为2 mm的液膜,在20~60 m管段预膜效果较好;水基缓蚀剂停止注入后,由于气流的冲刷作用,管壁缓蚀剂液膜逐渐被破坏和减薄。建议每隔60 m长管段增加一个缓蚀剂注入喷嘴,并且整个井筒缓蚀剂喷嘴的位置呈螺旋上升分布。

关键词:

缓蚀剂, 预膜, 气井, 欧拉壁膜, 数值模拟

Abstract:

Sour gas wells are often associated with the corrosion of metal materials caused by CO2 and H2S. The prefilm anticorrosion technology by water-based corrosion inhibitor injection is relatively advanced and low-cost. However,no systematic research has been carried out on the prefilm time,thickness and distribution of liquid film and corrosion inhibitor spray cycle. Based on RNG k- ε model,the multiphase flow theory and the EWF model were coupled to simulate the formation and flow of the water-based corrosion inhibitor liquid film,and the flow law of corrosion inhibitors subjected gas stream flushing after injection was analyzed. The results showed that the gas stream in the sour gas well can entrain water-based corrosion inhibitors and form a liquid film with a thickness of about 2 mm on the pipe wall under production conditions,and the prefilm performance is better in the pipe section between the 20~60 m positions. After the injection of water-based corrosion inhibitor is stopped,the liquid film of corrosion inhibitors on the pipe wall is gradually destroyed and thinned due to the flushing of gas streams. Therefore,it is recommended to install a corrosion inhibitor injection nozzle at an interval of 60 m along the pipe and place the corrosion inhibitor nozzles along the wellbore in a spiral manner.

Key words:

corrosion inhibitor, prefilm, gas well, Eulerian wall film, numerical simulation

中图分类号: