Deep-well well-control monitoring systems record multiple parameters using unified timestamps;however,synchronous acquisition does not imply synchronous response to a kick. Owing to wellbore propagation,sensor location,signal accumulation,and measurement-chain effects,effective anomaly information from different parameters may occur at different historical positions. To address this issue,50 independent simulation cases were generated by inverting field operating-condition boundary parameters. The optimal response position of each parameter was identified within a historical window to construct time-corrected inputs. The same Transformer time-series model was then used to compare four input schemes. The combined input achieved the best overall performance,with Accuracy,Precision,Recall,and F1 values of 0.886,0.922,0.794,and 0.798,respectively. Relative to the synchronous input,Accuracy,Precision,Recall,and F1 changed by +0.025,+0.059,-0.019,and +0.019,respectively,with Precision showing the largest positive improvement. The confidence intervals for all four paired differences crossed zero,indicating a numerical improvement trend rather than statistical significance at the current sample scale. The non-matched input performed less favorably overall,demonstrating that the improvement mainly arose from correctly matching each parameter to its historical response position. Time-lag analysis improves the temporal alignment of input features and can serve as a data-quality optimization method for intelligent well control.